VAM1502000F Total Heat Exchanger HRV (Heat Reclaim Ventilation) 4PW13545-1C The method of installation VAM150F, VAM250F, VAM350F, VAM500F VAM650F, VAM800F, VAM1000F, VAM1500F, VAM2000F Installation of duct connecting flanges Attach the provided duct connecting flanges using screws (accessories).
Product Highlights Product Range Capacities View AR View 360 DX coil cooling capacity Airflow rate 500-950 m3 /h Daikin’s HRV Heat Reclaim Ventilation recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. Equipped with a heat reclaim ventilator and a heat exchanger DX coil, VKM series is capable of minimizing room temperature fluctuations. VKM series maintains comfortable indoor air quality IAQ by adding fresh outdoor air having nearly the same temperature and humidity conditions as the indoor air. Thus, VKM ensures optimum comfort and further reduces air conditioning load. VKM – How It Works The fresh air is supplied to the office by air discharge grills connected to the VKM Supply Air duct. Heat Reclaim Ventilator + Heat Exchanger → Comfortable Air Supply Equipped with a heat reclaim ventilator and a heat exchanger, the new VKM series minimizes room temperature fluctuations. A Compact Unit Packed with Daikin’s Cutting-Edge Technologies. Air Conditioning and Outdoor Air Processing Can be Accomplished Using a Single System. When the VKM series units are connected, the total connection capacity index must be 50% to 130% of the capacity index of the outdoor units. Filtration Unit Option Removes particulate matter present in the outdoor air, as well as sulfur oxides and nitrogen oxides, providing clean fresh air to the indoor ambient. • filter Removes 99% or more of μm particulate matter. • Activated Carbon filter Removes sulfur oxides and nitrogen oxides Double-layered efficient filtration filters are double-layered. filters are double-layered. 1. The front filter effectively remove large particles. 2. The filter layer contains a large amount of static electricity to capture particulate matter effectively. Electrostatic Dust Collection Filter More Efficient and Longer Lasting Effect The filter layer contains a large amount of static electricity to capture particulate matter effectively, including those smaller than the grid mesh. The filter is difficult to be blocked by particles and has good ventilation and long life span. CO2 Sensor Optional Kit Connection for VAM / VKM Series The CO2 sensor controls airflow so that it best matches the changes of CO2 level in the room. This prevents energy losses from over-ventilation while maintaining indoor air quality with optional CO2 sensor. Tech specs Specifications ModelVKM50GCVEVKM80GCVEVKM100GCVE Power Consumption Heat Exchange modeW 270/230/170390/335/220440/370/260 Power Consumption Bypass modeW305/260/200390/335/220440/370/260 External static Pressure Pa210/170/140220/180/125170/120/90 Airflow rate m3/h500/500/440750/750/640950/950/820 Sound level Heat Exchange modedB43/ Sound level Bypass modedB43/41/ Temp exchange efficiency %76/76/ Enthalpy exchange efficiency %64/64/6766/66/6862/62/66 DX-coil Capacity kW Dimensions H x W x D387x1764x832387x1764x1214387x1764x1214 Machine weight kg92113115 You are now leaving Daikin Malaysia Once you link to another web site, you are subject to the terms and conditions of that web site, including but not limited to its privacy policy. CANCEL CONTINUE
Canbe connected only to VRV Heat Reclaim Ventilator Daikin's unique heat exchange element realizes efficient heat exchange between supply air and exhaust air. High external static pressure enables flexible installation. Heat Reclaim Ventilator with DX-Coil

Available in Capacities Refrigerant Daikin also offers heat reclaim ventilator systems; our VAM-HVE series are compact, energy efficient and can operate under a wide outdoor operating temperature range -15 to 50°C. These units provide high enthalpy efficiency due to the greatly enhanced performance of the thin film element. Furthermore, ESP of up to 235Pa offers greater design flexibility to your air conditioning solution. Other features include Night Purge Operation night time free-cooling, interlocked operation with VRV Cassette presence sensor and optional CO2, indoor & outdoor humidity sensors for optimal operation. By incorporating heat reclaim ventilators into your air conditioning design, heat loads can be reduced and your plan size can be better optimised. Download Brochure Engineering Data All Daikin air conditioners exceed MEPS requirements, in line with Daikin’s commitment to providing energy efficient, quiet, simple to use and reliable air conditioning solutions. Contact a Daikin Sales Engineer A Daikin Sales Engineer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business. AAF offers a comprehensive air filtration portfolio to provide clean air solutions for commercial and industrial applications.

ForAssistance: Call Our Customer Support: 768044407 / 011 7444044 To know more click here Residential Light Commercial Commercial Home > Commercial > Ventilation Units > Energy Recovery Ventilator VAM_GVJU Overview Features Resources This product is designed to maintain good indoor air quality by providing sufficient levels of fresh outside air and recover waste heat from extracted air leaving the conditioned zone. This new ERV unit is fully compatible with Daikin’s DIII-NET communications. Provides energy-saving heat recovery ventilation via a new heat exchanger with high temperature and enthalpy recovery efficiency Design flexibility thanks to high static pressure fans and the capability for use in a wide range of climates 5°F to 122°F DB and 80% RH or less* Wide range of functions such as independent operation, interlock with other HVAC systems and automatic night purge to reduce cooling loads and increase energy savings Interlocked simultaneous operation with VRV indoor units through a single controller Auto mode switches the ventilation mode total heat exchange mode to bypass mode according to the operating status of air conditioner system Pre-cooling/heating control function to delay the start of ventilation during air conditioner start-up for higher energy savings Supply and exhaust fresh-up operation modes to control pressure within a space Filter sign and display reset notifies when filter changes are required ESP as high as Sound levels as low as dBA for sound sensitive installation locations * Note Certified in accordance with the AHRI ERV Certification Program, which is based on AHRI Standard 1060. Certified units may be found in the AHRI Directory at Performance characteristics certified to AHRI Standard 1060 based on the following conditions - The cooling effectiveness shall be based on 95°F DB / 78°F WB for the entering supply air and 75°F DB / 63°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow. - The heating effectiveness shall be based on 35°F DB / 33°F WB for the entering supply air and 70°F DB / 58°F WB for the entering exhaust air, at a leaving supply airflow of both 100% and 75% of the rated airflow.
TheDaikin HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also reduces the load on the air conditioning system and conserves energy.

DaikinHeat Reclaim Ventilator (HRV) True Heat Recovery systems capable of extracting stale, moisture-laden air from inside your home and bringing in fresher, drier air simultaneously. View PDF

Nameor trademark Daikin Europe N.V. Product descrip-tion Model identifier VAM150FCVE VAM250FCVE Specific energy consumption (SEC) Cold climate kWh/ (m².a) Heat reclaim ventilation • VAM-FC9 5 Dimensional drawings 5 - 1 Dimensional Drawings. 560 718 25.4 9.5 12.2 VAM-FC9 4D099260 10 6

DaikinRooftop Package Units. Daikin's range of Rooftop Packaged Units have been developed specifically to suit commercial applications and are designed for flexible and easy installation. With a light cream colour, the flat top and compact design gives an aesthetic and neat appearance when installed in the line of sight.
CODE A5. RESULT: High pressure control in heating, freeze-up protection control in cooling Clogged air filter of indoor unit and short-circuit Defect of indoor unit heat exchanger thermistor. CODE: A6. RESULT: Fan motor locked, overload, overcurrent Defect of connector contact Defect of indoor unit PCB Defect of fan motor.